XFD514 NHS Ester *Same Structure to Alexa Fluor™ 514 NHS Ester*
Product key features
- Ex/Em: 518/543 nm
- Extinction coefficient: 80,000 cm-1M-1
- Reactive Group: NHS ester
- Easy Conjugation: Efficiently labels primary amines on proteins, ligands, and amine-modified oligonucleotides
- Bright and Stable: Offers high fluorescence intensity, photostability, and consistent performance across pH 4—10
- Hydrophilic: Prevents aggregation and enhances signal clarity for advanced imaging and live-cell applications
Product description
XFD514, manufactured by AAT Bioquest, is a green-fluorescent dye structurally identical to Alexa Fluor™ 514 (ThermoFisher). It is characterized by high photostability and exceptional brightness, making it highly suitable for advanced imaging and flow cytometry applications. The dye is water-soluble and remains pH-insensitive within a broad range (pH 4–10), ensuring consistent fluorescence performance across diverse experimental conditions. XFD514 offers robust and reliable labeling, enabling precise and reproducible results in fluorescence-based assays.
The N-hydroxysuccinimidyl (NHS) ester of XFD514 is a widely used reagent for the conjugation of this dye to proteins or antibodies. NHS esters react selectively and efficiently with primary amines (such as the side chains of lysine residues or aminosilane-coated surfaces) at pH 7-9, forming stable covalent amide bonds. This property makes XFD514 NHS ester an excellent choice for labeling proteins, amine-modified oligonucleotides, and other amine-containing molecules.
Example protocol
PREPARATION OF STOCK SOLUTIONS
Unless otherwise noted, all unused stock solutions should be divided into single-use aliquots and stored at -20 °C after preparation. Avoid repeated freeze-thaw cycles
Prepare a 1 mL protein labeling stock solution by mixing 100 µL of reaction buffer (such as 1 M sodium carbonate solution or 1 M phosphate buffer, pH ~9.0) with 900 µL of the target protein solution (e.g., an antibody with a protein concentration of at least 2 mg/mL, if possible).
Note: The pH of the protein solution (Solution A) should be 8.5 ± 0.5. If the pH of the protein solution is lower than 8.0, adjust it to within the 8.0-9.0 range using either 1 M sodium bicarbonate solution or 1 M phosphate buffer at pH 9.0.
Note: The protein should be dissolved in 1X phosphate-buffered saline (PBS), pH 7.2-7.4. If the protein is dissolved in Tris or glycine buffer, dialyze it against 1X PBS, pH 7.2-7.4, to remove any free amines or ammonium salts (such as ammonium sulfate and ammonium acetate) commonly used in protein precipitation.
Note: Antibodies that are impure or stabilized with bovine serum albumin (BSA) or gelatin may not label effectively. Additionally, sodium azide or thimerosal can interfere with the conjugation reaction. To achieve optimal labeling results, these preservatives should be removed through dialysis or spin column techniques.
Note: For optimal labeling efficiency, it is recommended to maintain a final protein concentration between 2-10 mg/mL. Protein concentrations below 2 mg/mL can significantly reduce conjugation efficiency.
To prepare a 10 mM stock solution of XFD514 NHS ester, add anhydrous DMSO directly to the vial of XFD514 NHS ester. Mix well by pipetting or vortexing.
Note: Prepare the dye stock solution (Solution B) before starting the conjugation, and use it promptly. Extended storage of the dye stock solution may reduce the dye activity. Solution B can be stored in the freezer for up to two weeks, provided it is protected from light and moisture. Avoid freeze-thaw cycles.
SAMPLE EXPERIMENTAL PROTOCOL
This protocol is designed for labeling Goat anti-mouse IgG with XFD514 NHS ester. Additional optimization may be required to adapt the protocol to your specific proteins.
Note: Each protein requires a distinct dye/protein ratio, which varies depending on the characteristics of the dye. Over-labeling a protein can negatively impact its binding affinity, whereas using a low dye-to-protein ratio in protein conjugates can result in reduced sensitivity.
Use a 10:1 molar ratio of Solution B (dye) to Solution A (protein) as the starting point: Add 5 µL of the dye stock solution (Solution B, assuming the dye stock solution is 10 mM) to the vial containing the protein solution (95 µL of Solution A) with effective shaking. The concentration of the protein is ~0.05 mM, assuming the protein concentration is 10 mg/mL and the molecular weight of the protein is ~200KD.
Note: We recommend using a 10:1 molar ratio of Solution B (dye)/Solution A (protein). If it is too low or too high, determine the optimal dye/protein ratio at 5:1, 15:1, and 20:1, respectively.
Continue to rotate or shake the reaction mixture at room temperature for 30-60 minutes.
The following protocol demonstrates the purification of a dye-protein conjugate using a Sephadex G-25 column.
Prepare the Sephadex G-25 column according to the manufacturer's instructions.
Carefully load the reaction mixture (from the "Run Conjugation Reaction" step) to the top of the Sephadex G-25 column.
Add PBS (pH 7.2-7.4) as soon as the sample runs just below the top resin surface.
Add more PBS (pH 7.2-7.4) to the desired sample to complete the column purification. Combine the fractions that contain the desired dye-protein conjugate.
Note: For immediate use, the dye-protein conjugate must be diluted with staining buffer, and aliquoted for multiple uses.
Note: For longer-term storage, the dye-protein conjugate solution needs to be concentrated or freeze-dried.
The Degree of Substitution (DOS) is a critical factor in characterizing dye-labeled proteins. Proteins with a lower DOS generally exhibit weaker fluorescence, while those with a higher DOS (e.g., DOS > 6) may also show reduced fluorescence. The optimal DOS for most antibodies typically ranges between 2 and 10, depending on the specific properties of both the dye and the protein. For effective labeling, it is recommended to achieve a DOS of 6-8 moles of XFD514 NHS ester per mole of antibody. The following steps outline the process for determining the DOS of XFD514 NHS ester-labeled proteins.
For accurate measurement of the absorption spectrum of a dye-protein conjugate, maintain the sample concentration between 1-10 µM, adjusting as needed based on the dye's extinction coefficient.
For most spectrophotometers, the sample (from the column fractions) needs to be diluted with de-ionized water so that the O.D. values are in the range of 0.1 to 0.9. The O.D. (absorbance) at 280 nm is the maximum absorption of protein, while 518 nm is the maximum absorption of XFD514 NHS ester. To obtain accurate DOS, ensure the conjugate is free of the non-conjugated dye.
You can calculate DOS using our tool by following this link:
Spectrum
Product family
Name | Excitation (nm) | Emission (nm) | Extinction coefficient (cm -1 M -1) | Correction Factor (260 nm) | Correction Factor (280 nm) |
XFD488 NHS Ester *Same Structure to Alexa Fluor™ 488 NHS Ester* | 499 | 520 | 71000 | 0.30 | 0.11 |
XFD350 NHS Ester *Same Structure to Alexa Fluor™ 350 NHS Ester* | 343 | 441 | 19000 | 0.25 | 0.19 |
XFD532 NHS Ester *Same Structure to Alexa Fluor™ 532 NHS Ester* | 534 | 553 | 81000 | 0.24 | 0.09 |
XFD594 NHS Ester *Same Structure to Alexa Fluor™ 594 NHS Ester* | 590 | 618 | 90000 | 0.43 | 0.56 |
XFD555 NHS Ester *Same Structure to Alexa Fluor™ 555 NHS Ester* | 553 | 568 | 150000 | 0.08 | 0.08 |
XFD647 NHS Ester *Same Structure to Alexa Fluor™ 647 NHS Ester* | 650 | 671 | 239000 | 0.00 | 0.03 |
XFD680 NHS Ester *Same Structure to Alexa Fluor™ 680 NHS Ester* | 681 | 704 | 184000 | 0.00 | 0.05 |
XFD700 NHS Ester *Same Structure to Alexa Fluor™ 700 NHS Ester* | 696 | 719 | 192000 | 0.00 | 0.07 |
XFD750 NHS Ester *Same Structure to Alexa Fluor™ 750 NHS Ester* | 752 | 776 | 240000 | 0.00 | 0.04 |
Show More (16) |
References
Authors: Ahishali, Bulent and Kaya, Mehmet
Journal: Methods in molecular biology (Clifton, N.J.) (2021): 87-103
Authors: van Zanten, Camila and Melnikau, Dzmitry and Ryder, Alan G
Journal: Journal of fluorescence (2021): 835-845
Authors: Gajdos, Tamás and Hopp, Béla and Erdélyi, Miklós
Journal: Journal of fluorescence (2020): 437-443
Authors: Karlsson, Joshua K G and Laude, Alex and Hall, Michael J and Harriman, Anthony
Journal: Chemistry (Weinheim an der Bergstrasse, Germany) (2019): 14983-14998
Authors: Fan, Sanjun and Webb, James E A and Yang, Ying and Nieves, Daniel J and Gonçales, Vinicius R and Tran, Jason and Hilzenrat, Geva and Kahram, Mohaddeseh and Tilley, Richard D and Gaus, Katharina and Gooding, J Justin
Journal: Angewandte Chemie (International ed. in English) (2019): 14495-14498