ROS Detection: ROS probe selection guide.
Posted August 19, 2019
Answer
Table 1. Intracellular reactive oxygen species (ROS) detection reagents and assay kits
ROS Species | ROS Brite™ 570 | ROS Brite™ 670 | ROS Brite™ 700 | ROS Brite™ HDCF | Amplite® ROS Green | Amplite® ROS Red |
Hydrogen Peroxide (H2O2) | + | + | + | +++ | +++ | +++ |
Hydroxyl radical (•OH) | ++ | ++ | ++ | + | + | + |
Tert-butyl-hyrdoperoxide (TBHP) | + | + | + | + | + | + |
Hypochlorous acid (HOCl) | - | + | ++ | - | + | - |
Superoxide anion (O2•-) | + | ++ | ++ | - | - | - |
Nitric Oxide (NO) | - | - | - | - | - | - |
Peroxynitrite anion (ONOO-) | - | - | - | - | - | - |
Cat No. | 22902 | 22903 | 16004 | 16053 | 22901 |
Table 2. Selective reactive oxygen species (ROS) detection reagents and assay kits.
ROS Species | OxiVision™ Green | OxiVision™ Blue | MitoROS™ 520 | MitoROS™ 580 | MitoROS™ OH580 |
Hydrogen Peroxide (H2O2) | +++ | +++ | - | - | - |
Hydroxyl radical (•OH) | - | - | - | - | +++ |
Tert-butyl-hyrdoperoxide (TBHP) | - | - | - | - | - |
Hypochlorous acid (HOCl) | - | - | - | - | - |
Superoxide anion (O2•-) | - | - | +++ | +++ | - |
Nitric Oxide (NO) | - | - | - | - | - |
Peroxynitrite anion (ONOO-) | - | - | - | - | - |
Cat No. | 16060 |