iFluor® 546 is a bright orange fluorescent dye. iFluor® 546-labeled anti-IgG conjugates exhibit bright fluorescence signal and good photostability. Used for stable signal generation in imaging and flow cytometry, the fluorescence intensity of iFluor® 546 conjugates is pH-insensitive from pH 4 to pH 11. The iFluor® 546-labeled antibody conjugates can be well excited with either Nd:YAG laser (~532 nm) or Helium-Neon laser (~543 nm). iFluor® 546 family has the spectral properties essentially identical to those of Alexa Fluor® 546. Under the same conditions we tested, iFluor® 546 antibody conjugates are brighter and more photostable than the corresponding Alexa Fluo® 546. These spectral and labeling characteristics make the iFluor® 546 dye family a superior alternative to Alexa Fluor® 546. In addition, iFluor® 546 secondary antibody conjugates give higher signal/background ratios than the corresponding Alexa Fluor® 546-labeled conjugates.

Spectrum

Product family

NameExcitation (nm)Emission (nm)Extinction coefficient (cm -1 M -1)Quantum yieldCorrection Factor (260 nm)Correction Factor (280 nm)
iFluor® 350 goat anti-mouse IgG (H+L)3454502000010.9510.830.23
iFluor® 405 goat anti-mouse IgG (H+L)4034273700010.9110.480.77
iFluor® 488 goat anti-mouse IgG (H+L)4915167500010.910.210.11
iFluor® 514 goat anti-mouse IgG (H+L)5115277500010.8310.2650.116
iFluor® 532 goat anti-mouse IgG (H+L)5375609000010.6810.260.16
iFluor® 555 goat anti-mouse IgG (H+L)55757010000010.6410.230.14
iFluor® 594 goat anti-mouse IgG (H+L)58760320000010.5310.050.04
iFluor® 633 goat anti-mouse IgG (H+L)64065425000010.2910.0620.044
iFluor® 647 goat anti-mouse IgG (H+L)65667025000010.2510.030.03
iFluor® 680 goat anti-mouse IgG (H+L)68470122000010.2310.0970.094
iFluor® 700 goat anti-mouse IgG (H+L)69071322000010.2310.090.04
iFluor® 750 goat anti-mouse IgG (H+L)75777927500010.1210.0440.039
iFluor® 790 goat anti-mouse IgG (H+L)78781225000010.1310.10.09
iFluor® 350 goat anti-mouse IgG (H+L) *Cross Adsorbed*3454502000010.9510.830.23
iFluor® 405 goat anti-mouse IgG (H+L) *Cross Adsorbed*4034273700010.9110.480.77
iFluor® 488 goat anti-mouse IgG (H+L) *Cross Adsorbed*4915167500010.910.210.11
iFluor® 514 goat anti-mouse IgG (H+L) *Cross Adsorbed*5115277500010.8310.2650.116
iFluor® 532 goat anti-mouse IgG (H+L) *Cross Adsorbed*5375609000010.6810.260.16
iFluor® 555 goat anti-mouse IgG (H+L) *Cross Adsorbed*55757010000010.6410.230.14
iFluor® 594 goat anti-mouse IgG (H+L) *Cross Adsorbed*58760320000010.5310.050.04
iFluor® 633 goat anti-mouse IgG (H+L) *Cross Adsorbed*64065425000010.2910.0620.044
iFluor® 647 goat anti-mouse IgG (H+L) *Cross Adsorbed*65667025000010.2510.030.03
iFluor® 680 goat anti-mouse IgG (H+L) *Cross Adsorbed*68470122000010.2310.0970.094
iFluor® 700 goat anti-mouse IgG (H+L) *Cross Adsorbed*69071322000010.2310.090.04
iFluor® 750 goat anti-mouse IgG (H+L) *Cross Adsorbed*75777927500010.1210.0440.039
iFluor® 790 goat anti-mouse IgG (H+L) *Cross Adsorbed*78781225000010.1310.10.09
iFluor® 568 goat anti-mouse IgG (H+L)56858710000010.5710.340.15
iFluor® 568 goat anti-mouse IgG (H+L) *Cross Adsorbed*56858710000010.5710.340.15
iFluor® 546 goat anti-rabbit IgG (H+L)54155710000010.6710.250.15
iFluor® 546 goat anti-rabbit IgG (H+L) *Cross Adsorbed*54155710000010.6710.250.15
iFluor® 800 goat anti-mouse IgG (H+L) 80182025000010.1110.030.08
iFluor® 800 goat anti-mouse IgG (H+L) *Cross Adsorbed*80182025000010.1110.030.08
iFluor® 810 goat anti-mouse IgG (H+L) 81182225000010.0510.090.15
iFluor® 810 goat anti-mouse IgG (H+L) *Cross Adsorbed*81182225000010.0510.090.15
iFluor® 820 goat anti-mouse IgG (H+L)82285025000010.110.16
iFluor® 820 goat anti-mouse IgG (H+L) *Cross Adsorbed*82285025000010.110.16
iFluor® 840 goat anti-mouse IgG (H+L)8368792000001-0.20.09
iFluor® 840 goat anti-mouse IgG (H+L) *Cross Adsorbed*8368792000001-0.20.09
iFluor® 860 goat anti-mouse IgG (H+L)85387825000010.10.14
iFluor® 860 goat anti-mouse IgG (H+L) *Cross Adsorbed*85387825000010.10.14
Show More (31)

Citations

View all 4 citations: Citation Explorer
Overexpression of CXCR2 predicts poor prognosis in patients with colorectal cancer.
Authors: Zhao, Jingkun and Ou, Baochi and Feng, Hao and Wang, Puxiongzhi and Yin, Shuai and Zhu, Congcong and Wang, Shenjie and Chen, Chun and Zheng, Minhua and Zong, Yaping and others, undefined
Journal: Oncotarget (2017)
Cadherin-12 enhances proliferation in colorectal cancer cells and increases progression by promoting EMT
Authors: Ma, Junjun and Zhao, Jingkun and Lu, Jun and Wang, Puxiongzhi and Feng, Hao and Zong, Yaping and Ou, Baochi and Zheng, Minhua and Lu, Aiguo
Journal: Tumor Biology (2016): 1--12
Transplantation of RADA16-BDNF peptide scaffold with human umbilical cord mesenchymal stem cells forced with CXCR4 and activated astrocytes for repair of traumatic brain injury
Authors: Shi, W and Huang, CJ and Xu, XD and Jin, GH and Huang, RQ and Huang, JF and Chen, YN and Ju, SQ and Wang, Y and Shi, YW and others, undefined
Journal: Acta Biomaterialia (2016): 247--261
The migration and differentiation of hUC-MSCsCXCR4/GFP encapsulated in BDNF/chitosan scaffolds for brain tissue engineering
Authors: Huang, Chuanjun and Zhao, Longxiang and Gu, Jun and Nie, Dekang and Chen, Yinan and Zuo, Hao and Huan, Wei and Shi, Jinlong and Chen, Jian and Shi, Wei
Journal: Biomedical Materials (2016): 035004

References

View all 191 references: Citation Explorer
Antiprothrombin antibodies in a patient with secondary antiphospholipid syndrome and bleeding
Authors: Gonzalez Leon R, Garcia Hern and ez FJ, Castillo Palma MJ, Sanchez Roman J.
Journal: Med Clin (Barc) (2011): 668
Assessment of EGFR/HER2 dimerization by FRET-FLIM utilizing Alexa-conjugated secondary antibodies in relation to targeted therapies in cancers
Authors: Waterhouse BR, Gijsen M, Barber PR, Tullis ID, Vojnovic B, Kong A.
Journal: Oncotarget (2011): 728
Falsely elevated tacrolimus levels caused by immunoassay interference secondary to beta-galactosidase antibodies in an infected liver transplant recipient
Authors: Knorr JP, Grewal KS, Balasubramanian M, Young N, Zaki R, Khanmoradi K, Araya V, Ortiz J.
Journal: Pharmacotherapy (2010): 954
Prevalence of anti-Epstein-Barr virus antibodies in children and adolescents with secondary immunodeficiency
Authors: Buckova A., undefined
Journal: Epidemiol Mikrobiol Imunol (2010): 133
Analysis of the effectiveness of reused primary and secondary antibodies in Western blotting analysis
Authors: Boonrod K, Roth B, Leong Ngar S, Krczal G.
Journal: Anal Biochem (2010): 124
Page updated on December 2, 2024

Ordering information

Price
Unit size
Catalog Number16457
Quantity
Add to cart

Additional ordering information

Telephone1-800-990-8053
Fax1-800-609-2943
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
Technical SupportContact us
Purchase orderSend to sales@aatbio.com
ShippingStandard overnight for United States, inquire for international
Request quotation

Physical properties

Molecular weight

~150000

Solvent

Water

Spectral properties

Correction Factor (260 nm)

0.25

Correction Factor (280 nm)

0.15

Extinction coefficient (cm -1 M -1)

1000001

Excitation (nm)

541

Emission (nm)

557

Quantum yield

0.671

Storage, safety and handling

H-phraseH303, H313, H333
Hazard symbolXN
Intended useResearch Use Only (RUO)
R-phraseR20, R21, R22

Storage

Freeze (< -15 °C); Minimize light exposure
UNSPSC12171501