logo
AAT Bioquest

ATTO 700 NHS ester

ATTO 700 is a near-infrared fluorescent dye characterized by its strong absorption, high photo and thermal stability, and good aqueous solubility. It is optimally excited within the 670-715 nm wavelength range. As a zwitterionic compound, ATTO 700 remains electrically neutral when conjugated to biomolecules or other substrates. Its strong electron-accepting properties result in efficient fluorescence quenching by electron donors such as guanine and tryptophan. These properties make ATTO 700 ideal for precise applications including single-molecule detection and super-resolution microscopy techniques like PALM, dSTORM, and STED. Furthermore, ATTO 700 is compatible with flow cytometry (FACS), fluorescence in situ hybridization (FISH), and a variety of other biological assays, making it a versatile tool in advanced fluorescence-based research.

The N-hydroxysuccinimidyl (NHS) ester of ATTO 700 is a widely used reagent for the conjugation of this dye to proteins or antibodies. NHS esters react selectively and efficiently with primary amines (such as the side chains of lysine residues or aminosilane-coated surfaces) at pH 7-9, forming stable covalent amide bonds. This property makes ATTO 700 NHS ester an excellent choice for labeling proteins, amine-modified oligonucleotides, and other amine-containing molecules.

Example protocol

PREPARATION OF STOCK SOLUTIONS

Unless otherwise noted, all unused stock solutions should be divided into single-use aliquots and stored at -20 °C after preparation. Avoid repeated freeze-thaw cycles

Protein Stock Solution (Solution A)
  1. Mix 100 µL of a reaction buffer (e.g., 1 M  sodium carbonate solution or 1 M phosphate buffer with pH ~9.0) with 900 µL of the target protein solution (e.g., antibody, protein concentration >2 mg/mL if possible) to give 1 mL protein labeling stock solution.

    Note: The pH of the protein solution (Solution A) should be 8.5 ± 0.5. If the pH of the protein solution is lower than 8.0, adjust the pH to the range of 8.0-9.0 using 1 M  sodium bicarbonate solution or 1 M pH 9.0 phosphate buffer.

    Note: The protein should be dissolved in 1X phosphate buffered saline (PBS), pH 7.2-7.4. If the protein is dissolved in Tris or glycine buffer, it must be dialyzed against 1X PBS, pH 7.2-7.4, to remove free amines or ammonium salts (such as ammonium sulfate and ammonium acetate) that are widely used for protein precipitation.

    Note: Impure antibodies or antibodies stabilized with bovine serum albumin (BSA) or gelatin will not be labeled well. The presence of sodium azide or thimerosal might also interfere with the conjugation reaction. Sodium azide or thimerosal can be removed by dialysis or spin column for optimal labeling results.

    Note: The conjugation efficiency is significantly reduced if the protein concentration is less than 2 mg/mL. The final protein concentration range of 2-10 mg/mL is recommended for optimal labeling efficiency.

ATTO 700 NHS ester Stock Solution (Solution B)
  1. Add anhydrous DMSO into the vial of ATTO 700 NHS ester to make a 10 mM stock solution. Mix well by pipetting or vortex.

    Note: Prepare the dye stock solution (Solution B) before starting the conjugation. Use promptly. Extended storage of the dye stock solution may reduce the dye activity. Solution B can be stored in the freezer for two weeks when kept from light and moisture. Avoid freeze-thaw cycles.

SAMPLE EXPERIMENTAL PROTOCOL

This labeling protocol was developed for the conjugate of Goat anti-mouse IgG with ATTO 700 NHS ester. You might need further optimization for your particular proteins.

Note: Each protein requires a distinct dye/protein ratio, which also depends on the properties of dyes. Over-labeling of a protein could detrimentally affect its binding affinity, while the protein conjugates of low dye/protein ratio give reduced sensitivity.

Run the Conjugation Reaction
  1. Use a 10:1 molar ratio of Solution B (dye)/Solution A (protein) as the starting point:  Add 5 µL of the dye stock solution (Solution B, assuming the dye stock solution is 10 mM) into the vial of the protein solution (95 µL of Solution A) with effective shaking. The concentration of the protein is ~0.05 mM assuming the protein concentration is 10 mg/mL, and the molecular weight of the protein is ~200KD.

    Note: We recommend using a 10:1 molar ratio of Solution B (dye)/Solution A (protein). If it is too less or too high, determine the optimal dye/protein ratio at 5:1, 15:1, and 20:1, respectively.

  2. Continue to rotate or shake the reaction mixture at room temperature for 30-60 minutes.

Purify the Conjugate

The following protocol is an example of dye-protein conjugate purification by using a Sephadex G-25 column.

  1. Prepare the Sephadex G-25 column according to the manufacturer's instructions.

  2. Load the reaction mixture (From "Run conjugation reaction") to the top of the Sephadex G-25 column.

  3. Add PBS (pH 7.2-7.4) as soon as the sample runs just below the top resin surface.

  4. Add more PBS (pH 7.2-7.4) to the desired sample to complete the column purification. Combine the fractions that contain the desired dye-protein conjugate.

    Note: For immediate use, the dye-protein conjugate must be diluted with staining buffer, and aliquoted for multiple uses.

    Note: For longer-term storage, the dye-protein conjugate solution needs to be concentrated or freeze-dried.

Characterize the Desired Dye-Protein Conjugate

The Degree of Substitution (DOS) is the most important factor for characterizing dye-labeled protein. Proteins of lower DOS usually have weaker fluorescence intensity, but proteins of higher DOS (e.g., DOS > 6) tend to have reduced fluorescence too. The optimal DOS for most antibodies is recommended between 2 and 10, depending on the properties of dye and protein. For effective labeling, the degree of substitution should be controlled to have 6-8 moles of ATTO 700 NHS ester to one mole of antibody. The following steps are used to determine the DOS of ATTO 700 NHS ester-labeled proteins.

Measure Absorption

To measure the absorption spectrum of a dye-protein conjugate, it is recommended to keep the sample concentration in the range of 1-10 µM depending on the extinction coefficient of the dye.

Read OD (absorbance) at 280 nm and dye maximum absorption (ƛmax = 715 nm for ATTO 700 NHS ester)

For most spectrophotometers, the sample (from the column fractions) needs to be diluted with de-ionized water so that the O.D. values are in the range of 0.1 to 0.9. The O.D. (absorbance) at 280 nm is the maximum absorption of protein, while 715 nm is the maximum absorption of ATTO 700 NHS ester. To obtain accurate DOS, ensure the conjugate is free of the non-conjugated dye.

Calculate DOS

You can calculate the DOS using our tool by following this link:

https://www.aatbio.com/tools/degree-of-labeling-calculator 

Spectrum

Product family

NameExcitation (nm)Emission (nm)Extinction coefficient (cm -1 M -1)Quantum yieldCorrection Factor (260 nm)Correction Factor (280 nm)
ATTO 488 NHS ester499520900000.800.220.09
ATTO 532 NHS ester5315521150000.900.220.11
ATTO 647 NHS ester6466661200000.200.080.04
ATTO 647N NHS ester6456631500000.6510.060.05
ATTO 594 NHS ester6026211200000.850.260.51
ATTO 514 NHS ester510531115,0000.850.210.08
ATTO 565 NHS ester5625891200000.900.270.12
ATTO 390 NHS ester39047524000.900.460.09
ATTO 425 NHS ester438484450000.900.190.17
ATTO 495 NHS ester497525800000.20.450.37
ATTO 550 NHS ester5535741200000.800.230.10
ATTO 590 NHS ester5926211200000.800.390.43
ATTO 610 NHS ester6156321500000.700.030.06
ATTO 620 NHS ester61964112000010.510.040.06
ATTO 633 NHS ester6296511300000.6410.040.05
ATTO 655 NHS ester6616791250000.310.240.08
ATTO 680 NHS ester6796961250000.300.300.17
Show More (8)

References

View all 6 references: Citation Explorer
Whole blood multiplex measurements using electrochemical aptamer-based biosensors.
Authors: d'Astous, Élodie V and Dauphin-Ducharme, Philippe
Journal: Chemical communications (Cambridge, England) (2024): 6419-6422
Multiphoton absorption enhancement by graphene-gold nanostructure.
Authors: Izadshenas Jahromi, Saeid and Słowik, Karolina
Journal: Optics letters (2024): 3914-3917
Near infrared-emitting multimodal nanosystem for in vitro magnetic hyperthermia of hepatocellular carcinoma and dual imaging of in vivo liver fibrosis.
Authors: Nazeer, Shaiju S and Saraswathy, Ariya and Nimi, Nirmala and Santhakumar, Hema and Radhakrishnapillai Suma, Parvathy and Shenoy, Sachin J and Jayasree, Ramapurath S
Journal: Scientific reports (2023): 12947
Spatial distribution of single guest molecules along thickness of thin films of poly(2-hydroxyethyl acrylate).
Authors: Ito, Syoji and Hiratsuka, Kengo and Takei, Satoshi and Nishi, Hiroyasu and Kitagawa, Daichi and Kobatake, Seiya and Miyasaka, Hiroshi
Journal: Photochemical & photobiological sciences : Official journal of the European Photochemistry Association and the European Society (2022): 175-184
Application of single molecule fluorescence microscopy to characterize the penetration of a large amphiphilic molecule in the stratum corneum of human skin.
Authors: Volz, Pierre and Boreham, Alexander and Wolf, Alexander and Kim, Tai-Yang and Balke, Jens and Frombach, Janna and Hadam, Sabrina and Afraz, Zahra and Rancan, Fiorenza and Blume-Peytavi, Ulrike and Vogt, Annika and Alexiev, Ulrike
Journal: International journal of molecular sciences (2015): 6960-77
Page created on August 22, 2024, last updated on September 1, 2024

Ordering information

Price
Unit size
Catalog Number70301
Quantity
Add to cart

Additional ordering information

Telephone1-800-990-8053
Fax1-800-609-2943
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
Technical SupportContact us
Purchase orderSend to sales@aatbio.com
ShippingStandard overnight for United States, inquire for international
Request quotation

Physical properties

Molecular weight

662.76

Solvent

DMSO

Spectral properties

Correction Factor (260 nm)

0.26

Correction Factor (280 nm)

0.41

Extinction coefficient (cm -1 M -1)

120000

Excitation (nm)

699

Emission (nm)

715

Quantum yield

0.25

Storage, safety and handling

Certificate of OriginDownload PDF
H-phraseH303, H313, H333
Hazard symbolXN
Intended useResearch Use Only (RUO)
R-phraseR20, R21, R22

Storage

Freeze (< -15 °C); Minimize light exposure
UNSPSC12352200
Product Image
Product Image
Gallery Image 1