Buccutite™ Rapid Oligo Antibody Conjugation Kit *Optimized for Labeling 100 ug Protein*
Example protocol
AT A GLANCE
Protein molecular weight: >25,000 Daltons
Protein concentration: >=1mg/mL
Protein sample volume: 60~120 μL
PREPARATION OF WORKING SOLUTION
To label 100 μg protein (assuming that the concentration is 1 mg/mL in PBS), mix 5 μL (5% of the total reaction volume) of Reaction Buffer (Component C) with 100 μL of the protein solution.
Note: The protein should be dissolved in 1X phosphate-buffered saline (PBS), pH 7.2-7.4. If the protein is dissolved in glycine buffer, it must be dialyzed against 1X PBS, pH 7.2-7.4, or use ReadiUse™ 10KD Spin Filter (Cat No. 60502) to remove free amines or ammonium salts, such as ammonium sulfate and ammonium acetate, that are widely used for protein precipitation.
Note: Impure proteins or proteins stabilized with bovine serum albumin (BSA) or gelatin will not label well.
To label 200 μg of an amine-labeled oligo (assuming a concentration of 2 mg/mL), mix 5 μL (5% of the total reaction volume) of the Reaction Buffer (Component C) with 100 μL of the oligo solution.
Note: The oligo should be dissolved in nuclease-free water for better results.
SAMPLE EXPERIMENTAL PROTOCOL
Add 105 μL of the protein solution directly to the vial of Buccutite™ FOL (Component A). Mix well by pipetting or vortexing.
Keep the protein-Buccutite™ FOL reaction mixture at room temperature for 30 - 60 minutes.
Note: The protein-Buccutite™ FOL reaction mixture can be rotated or shaken for a longer time if desired.
Purify the protein-Buccutite™ FOL reaction mixture using the desalting column. Please refer to the 'Prepare spin column for Antibody purification' section below for detailed instructions.
Calculate the concentration of the protein-Buccutite™ FOL mixture with 75% yield after desalting. (For example: if starting with 100 μg protein, after desalting column purification, the recovery protein amount is ~75μg.)
Add 105 μL of the amine-labeled oligo solution directly to the vial of Buccutite™ MTA (Component B). Mix well by pipetting or vortexing.
Keep the oligo-Buccutite™ MTA reaction mixture at room temperature for 30 - 60 minutes.
Note: The oligo-Buccutite™ MTA reaction mixture can be rotated or shaken for a longer time if desired.
Purify the oligo-Buccutite™ MTA reaction mixture using alcohol precipitation. Please refer to the 'Purification of Oligo with Alcohol Precipitation' section below for detailed instructions.
To start the conjugation reaction, mix the protein-Buccutite™ FOL reaction mixture with the oligo-Buccutite™ MTA reaction mixture at the desired molar ratio.
Note: You can adjust the mixing ratio depending on your downstream applications and the cost of your proteins.
Rotate the mixture for 1-2 hours at room temperature or at 4°C overnight. The reaction mixture is ready for immediate use or can be stored at 4°C.
Note: Desalting is optional.
A small amount of the reaction mixture, such as 2-4 μg, can be analysed using a 4-12% Bis-Tris Protein Gel in an SDS running buffer system to verify the conjugation outcome.
The conjugation reaction mixture contains both the desired conjugate and a small amount of unconjugated oligo. If required, the reaction mixture can be purified by size exclusion chromatography (SEC), and the desired conjugate fractions can be pooled and combined.
Invert the provided spin column (Component D) several times to re-suspend the settled gel and remove any bubbles.
Snap off the tip and place the column in a washing tube (2 mL, not provided). Remove the cap to allow the excess packing buffer to drain by gravity to the top of the gel bed.
Note: If the column does not begin to flow, push the cap back into the column and remove it again to start the flow. Discard the drained buffer, and then place the column back into the Washing Tube.
Centrifuge at 1000 x g for 2 minutes in a swinging bucket centrifuge to remove the packing buffer. Then discard the buffer. Refer to the 'Centrifugation Notes' section below for instructions.
Apply 1-2 mL 1X PBS (pH 7.2-7.4) to the column. After each application of PBS, let the buffer drain out by gravity, or centrifuge the column for 2 minutes to remove the buffer. Discard the buffer from the collection tube. Repeat this process for 3-4 times.
Centrifuge at 1000 x g for 2 minutes in a swinging bucket centrifuge to remove the packing buffer. Then discard the buffer. Refer to the 'Centrifugation Notes' section below for detailed instructions.
Place the column into a clean collecting tube (1.5 mL, not provided). Then, take 105 µL of the protein-Buccutite™ FOL reaction mixture from step 2 of the "Run Protein-Buccutite™ FOL Reaction" section and load it carefully and directly into the center of the column.
After loading the sample, add 10 μL of 1X PBS (pH 7.2-7.4), centrifuge the column for 5-6 minutes at 1,000 x g, and collect the solution that contains the desired protein-Buccutite™ FOL solution.
Add 0.1 volume (10 uL) of 5M sodium chloride and 2 - 2.5 volumes of ice-cold 100% ethanol (250 uL) to the oligo-Buccutite™ MTA reaction mixture. Mix well and place at ≤ -20°C for at least 30 minutes.
Centrifuge at full speed (>14,000 x g) in a refrigerated micro centrifuge for 15-30 minutes to pellet the labeled nucleic acid. Once pelleted, gently remove the ethanol with a micropipette; do not disturb the pellet.
Note: Small nucleic acid quantities can be difficult to visualize. Mark and orient the precipitate-containing tubes in the microfuge such that the pellet will form in a predetermined place.
Wash the pellet once with 500 μL of room temperature 70% ethanol. Centrifuge at full speed for an additional 15-30 minutes.
Remove all traces of ethanol with a micropipette. DO NOT allow the sample to dry beyond 5 minutes as the pellet may become difficult to re-suspend.
Re-suspend the labeled oligo with sterile water (we recommended adding 30 uL of water).
Store the purified, labeled oligo on ice for immediate use.
The spin column (Component D) can fit into a 2 mL microcentrifuge tube or 12 x 75 mm test tube for sample collection during centrifugation. Use the 2 mL microtube with the columns for the initial column equilibration step.
Swinging bucket centrifuges are capable of generating a minimum force of 1,000 x g and are suitable for Bio-Spin column use. The gravitational force created at a particular revolution speed is a function of the radius of the microcentrifuge rotor. Consult the swinging bucket centrifuge instruction manual for information about conversion from revolutions per minute (RPM) to centrifugal or g-force. Alternatively, use the following equation to calculate the speed in RPM required to reach the gravitational force of 1,000 x g.
Alternatively, use the following equation to calculate the speed in RPM required to reach the gravitational force of 1,000 x g:
RCF (x g) = (1.12 x 10-5) × (RPM) × 2 × r
- RCF is the relative centrifugal force.
- r is the radius in centimeters measured from the center of the rotor to the middle of the Bio-Spin column.
- RPM is the speed of the rotor.
References
Authors: Jahanbani, Shaghayegh and Hansen, Paige S and Blum, Lisa K and Bastounis, Effie E and Ramadoss, Nitya S and Pandrala, Mallesh and Kirschmann, Jessica Marie and Blacker, Grace Sisemore and Love, Zelda Z and Weissman, Irving L and Nemati, Fahimeh and Tal, Michal Caspi and Robinson, William H
Journal: Clinical immunology (Orlando, Fla.) (2023): 109180
Authors: Shi, Xiaoshan and Fan, Wei and Mehrpouyan, Majid and Chen, Yu and D'Cruz, Louise M and Widmann, Stephanie J and Tyznik, Aaron J
Journal: Cytometry. Part A : the journal of the International Society for Analytical Cytology (2023)
Authors: Li, Xiaoyi and Feng, Zhihao and Fang, Changxiang and Wei, Yunpeng and Ji, Dandan and Hu, Weihua
Journal: Lab on a chip (2023): 2477-2486
Authors: Shrock, Ellen L and Shrock, Christine L and Elledge, Stephen J
Journal: Bio-protocol (2022)
Authors: Soma, Emi and Yamayoshi, Asako and Toda, Yuki and Mishima, Yuji and Hosogi, Shigekuni and Ashihara, Eishi
Journal: Cancers (2022)