RatioWorks™ PH165, NHS ester
RatioWorks™ PH165 NHS ester is a novel fluorescent probe that can be used to measure intracellular pH in live cells. It shows pH-dependent fluorescence spectra. Its dual excitation and dual emission make it a unique ratiometric pH probe for analyzing live cells. At low pH, RatioWorks™ PH165 is weakly fluorescent in far red spectrum region and highly fluorescent in red spectrum region. As pH increases, it shows higher fluorescence in far red spectrum and lower fluorescence in red spectrum. This probe can quantify cytosolic pH in the range from 4 to 9 with dual excitation/emission at 497/594 nm and 578/654 nm respectively. The pKa of PH165 is ~7.1. The red fluorescence spectrum of RatioWorks™ PH165 makes it suitable for multiplexing tests with green fluorophores such as GFP. The amine-reactive RatioWorks™ PH165 NHS ester is an excellent building block for developing novel ratiometric fluorescent probes of a variety of biological applications that require the precise pH determinations with the minimal effect of pH probe concentration change.
Spectrum
Open in Advanced Spectrum Viewer
Citations
View all 3 citations: Citation Explorer
Intracellular pH Measurements in Glioblastoma Cells Using the pH-Sensitive Dye BCECF
Authors: Galifianakis, N. V., Placantonakis, D. G., Chesler, M.
Journal: Methods Mol Biol (2018): 103-109
Authors: Galifianakis, N. V., Placantonakis, D. G., Chesler, M.
Journal: Methods Mol Biol (2018): 103-109
Evaluation of BCECF fluorescence ratio imaging to properly measure gastric intramucosal pH variations in vivo
Authors: Rochon, P., Jourdain, M., Mangalaboyi, J., Fourrier, F., Soulie-Begu, S., Buys, B., Dehlin, G., Lesage, J. C., Chambrin, M. C., Mordon, S.
Journal: J Biomed Opt (2007): 064014
Authors: Rochon, P., Jourdain, M., Mangalaboyi, J., Fourrier, F., Soulie-Begu, S., Buys, B., Dehlin, G., Lesage, J. C., Chambrin, M. C., Mordon, S.
Journal: J Biomed Opt (2007): 064014
Calibration methods and avoidance of errors in measurement of intracellular pH (pHcyt) using the indicator bis(carboxyethyl)-5(6)-carboxyfluorescein (BCECF) in human platelets
Authors: Valant, P. A., Haynes, D. H.
Journal: J Fluoresc (1992): 191-206
Authors: Valant, P. A., Haynes, D. H.
Journal: J Fluoresc (1992): 191-206
References
View all 1 references: Citation Explorer
Estimation of intramitochondrial pca and ph by fura-2 and 2,7 biscarboxyethyl-5(6)-carboxyfluorescein (bcecf) fluorescence
Authors: Davis MH, Altschuld RA, Jung DW, Brierley GP.
Journal: Biochem Biophys Res Commun (1987): 40
Authors: Davis MH, Altschuld RA, Jung DW, Brierley GP.
Journal: Biochem Biophys Res Commun (1987): 40