mFluor™ Blue 620 dye can be well excited with blue laser at 488 nm. It has a huge Stokes shift with emission ~620 nm. mFluor™ Blue 620 dyes are water-soluble, and the protein conjugates prepared with mFluor™ Blue 620 dyes are well excited at 488 nm to give red fluorescence. mFluor™ Blue 620 dye and conjugates are excellent blue laser reagents for flow cytometry detections. Compared to RPE, mFluor™ Blue 620 dyes are much more photostable, making them readily available for fluorescence imaging applications while it is very difficult to use RPE conjugates for fluorescence imaging applications due to the rapid photobleaching of RPE conjugates. It is also a unique fluorochrome for spectral flow cytometry since there are very few existing dyes that have this spectral profile.

Example protocol

PREPARATION OF STOCK SOLUTIONS

Unless otherwise noted, all unused stock solutions should be divided into single-use aliquots and stored at -20 °C after preparation. Avoid repeated freeze-thaw cycles

Protein stock solution (Solution A)
  1. Mix 100 µL of a reaction buffer (e.g., 1 M  sodium carbonate solution or 1 M phosphate buffer with pH ~9.0) with 900 µL of the target protein solution (e.g., antibody, protein concentration >2 mg/mL if possible) to give 1 mL protein labeling stock solution.

    Note: The pH of the protein solution (Solution A) should be 8.5 ± 0.5. If it is lower than 8.0, adjust it to 8.0-9.0 using 1 M  sodium bicarbonate solution or 1 M pH 9.0 phosphate buffer.

    Note: The protein should be dissolved in 1X phosphate-buffered saline (PBS), pH 7.2-7.4. If the protein is dissolved in Tris or glycine buffer, it must be dialyzed against 1X PBS, pH 7.2-7.4, to remove free amines or ammonium salts (such as ammonium sulfate and ammonium acetate) that are widely used for protein precipitation.

    Note: Impure antibodies or antibodies stabilized with bovine serum albumin (BSA) or gelatin will not be labeled well. The presence of sodium azide or thimerosal might also interfere with the conjugation reaction. For optimal labeling results, sodium azide or thimerosal can be removed by dialysis or spin column.

    Note: The conjugation efficiency is significantly reduced if the protein concentration is less than 2 mg/mL. For optimal labeling efficiency, the final protein concentration range of 2-10 mg/mL is recommended.

mFluor™ Blue 620 SE stock solution (Solution B)
  1. Add anhydrous DMSO into the vial of mFluor™ Blue 620 SE to make a 10 mM stock solution. Mix well by pipetting or vortex.

    Note: Prepare the dye stock solution (Solution B) before starting the conjugation. Use promptly. Extended storage of the dye stock solution may reduce the dye activity. Solution B can be stored in a freezer for two weeks when kept from light and moisture. Avoid freeze-thaw cycles.

SAMPLE EXPERIMENTAL PROTOCOL

This labeling protocol was developed for the conjugate of Goat anti-mouse IgG with mFluor™ Blue 620 SE. You might need further optimization for your particular proteins.

Each protein requires a distinct dye/protein ratio, which also depends on the properties of the dyes. Over-labeling of a protein could detrimentally affect its binding affinity while the protein conjugates of low dye/protein ratio give reduced sensitivity.

Run conjugation reaction
  1. Use a 10:1 molar ratio of Solution B (dye)/Solution A (protein) as the starting point:  Add 5 µL of the dye stock solution (Solution B, assuming the dye stock solution is 10 mM) into the vial of the protein solution (95 µL of Solution A) with effective shaking. The concentration of the protein is ~0.05 mM, assuming the protein concentration is 10 mg/mL and the molecular weight of the protein is ~200KD.

    Note: We recommend using a 10:1 molar ratio of Solution B (dye)/Solution A (protein). If it is too low or too high, determine the optimal dye/protein ratio at 5:1, 15:1, and 20:1, respectively.

  2. Continue to rotate or shake the reaction mixture at room temperature for 30-60 minutes.
Purify the conjugation

The following protocol is an example of dye-protein conjugate purification by using a Sephadex G-25 column.

  1. Prepare Sephadex G-25 column according to the manufacture instruction.
  2. Load the reaction mixture (From "Run conjugation reaction") to the top of the Sephadex G-25 column.
  3. Add PBS (pH 7.2-7.4) as soon as the sample runs just below the top resin surface.
  4. Add more PBS (pH 7.2-7.4) to the desired sample to complete the column purification. Combine the fractions that contain the desired dye-protein conjugate.

    Note: For immediate use, dilute the dye-protein conjugate with staining buffer and aliquot for multiple uses.

    Note: For longer-term storage, the dye-protein conjugate solution must be concentrated or freeze-dried.

Spectrum

Product family

NameExcitation (nm)Emission (nm)Extinction coefficient (cm -1 M -1)Correction Factor (260 nm)Correction Factor (280 nm)
mFluor™ Green 620 SE5256235000010.8950.569

References

View all 21 references: Citation Explorer
A Comprehensive Workflow for Applying Single-Cell Clustering and Pseudotime Analysis to Flow Cytometry Data.
Authors: Melsen, Janine E and van Ostaijen-Ten Dam, Monique M and Lankester, Arjan C and Schilham, Marco W and van den Akker, Erik B
Journal: Journal of immunology (Baltimore, Md. : 1950) (2020)
High-Dimensional Data Analysis Algorithms Yield Comparable Results for Mass Cytometry and Spectral Flow Cytometry Data.
Authors: Ferrer-Font, Laura and Mayer, Johannes U and Old, Samuel and Hermans, Ian F and Irish, Jonathan and Price, Kylie M
Journal: Cytometry. Part A : the journal of the International Society for Analytical Cytology (2020)
HTLV infected individuals have increased B-cell activation and proinflammatory regulatory T-cells.
Authors: Kjerulff, Bertram and Petersen, Mikkel Steen and Rodrigues, Candida Medina and da Silva Té, David and Christiansen, Mette and Erikstrup, Christian and Hønge, Bo Langhoff
Journal: Immunobiology (2020): 151878
Multispectral Flow Cytometry: Unaddressed Issues and Recommendations for Improvement.
Authors: Parks, David R
Journal: Cytometry. Part A : the journal of the International Society for Analytical Cytology (2020)
High-dimensional analysis of intestinal immune cells during helminth infection.
Authors: Ferrer-Font, Laura and Mehta, Palak and Harmos, Phoebe and Schmidt, Alfonso J and Chappell, Sally and Price, Kylie M and Hermans, Ian F and Ronchese, Franca and le Gros, Graham and Mayer, Johannes U
Journal: eLife (2020)
Page updated on December 17, 2024

Ordering information

Price
Unit size
Catalog Number1163
Quantity
Add to cart

Additional ordering information

Telephone1-800-990-8053
Fax1-800-609-2943
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
Technical SupportContact us
Purchase orderSend to sales@aatbio.com
ShippingStandard overnight for United States, inquire for international
Request quotation

Physical properties

Molecular weight

1743.06

Solvent

DMSO

Spectral properties

Absorbance (nm)

591

Correction Factor (260 nm)

0.683

Correction Factor (280 nm)

0.849

Extinction coefficient (cm -1 M -1)

980001

Excitation (nm)

589

Emission (nm)

616

Quantum yield

0.181

Storage, safety and handling

H-phraseH303, H313, H333
Hazard symbolXN
Intended useResearch Use Only (RUO)
R-phraseR20, R21, R22

Storage

Freeze (< -15 °C); Minimize light exposure
UNSPSC12171501
Flow cytometry analysis of whole blood stained with mFluor™ Blue 620 anti-human CD4 *SK3* conjugate. The fluorescence signal was monitored using an Aurora spectral flow cytometer in the mFluor™ Blue 620 specific B7-A channel.
Flow cytometry analysis of whole blood stained with mFluor™ Blue 620 anti-human CD4 *SK3* conjugate. The fluorescence signal was monitored using an Aurora spectral flow cytometer in the mFluor™ Blue 620 specific B7-A channel.
Flow cytometry analysis of whole blood stained with mFluor™ Blue 620 anti-human CD4 *SK3* conjugate. The fluorescence signal was monitored using an Aurora spectral flow cytometer in the mFluor™ Blue 620 specific B7-A channel.
Fluorescent dye NHS esters (or succinimidyl esters) are the most popular tool for conjugating dyes to a peptide, protein, antibody, amino-modified oligonucleotide, or nucleic acid. NHS esters react readily with the primary amines (R-NH<sub>2</sub>) of proteins, amine-modified oligonucleotides, and other amine-containing molecules. The resulting dye conjugates are quite stable.